A
AIG Sentinel
Demo ยท Western Council
๐Ÿ‡ฆ๐Ÿ‡บ NSW LG ยท v1
โ† Back to marketing site
BM
Bob Millward
Governance Lead

UC-002_predictive_maint_model_test_results_v1.xlsx

EV-2026-0146 ยท Test Results ยท linked to Predictive maintenance โ€” water mains

โ† Back to vault
Artefact ID
EV-2026-0146
Type
Test Results
Linked use case
Uploaded by
Linda Park
Uploaded at
2026-05-25 11:08
Size
1248 KB
SHA-256
5e2cโ€ฆa87b (truncated for display)
Hash chain
Verified ยท chained to previous entry
Summary

Holdout test set results for the predictive maintenance XGBoost model. Tested on final 12 months of historical data not seen during training. Meets AIRC condition (FP < 15%).

Chain of custody

Generated by Linda Park via Azure ML notebook 'pred-maint-eval-v1'. Hash chained on upload.

Key facts

Test window
1 May 2025 โ€“ 30 April 2026
Events tested
2,418 (including 187 confirmed failures)
Suburbs covered
All 9 pilot zone suburbs (Westbrook CBD)
Model version
xgb-v1.0.4 (training run 2026-05-18 17:42 AEST)

Headline metrics โ€” test set (12 months holdout, 2,418 events)

MetricValueAIRC thresholdPass / fail
F1 score0.71โ‰ฅ 0.65โœ“ Pass
Precision0.74โ‰ฅ 0.70โœ“ Pass
Recall0.68โ‰ฅ 0.60โœ“ Pass
False positive rate11.2%< 15%โœ“ Pass
False negative rate8.4%< 20%โœ“ Pass
Lead time (median, days)27โ‰ฅ 21โœ“ Pass